ACE=0, DIAGVAL=00, ADPRC=00, ADRFMT=0, DIAGM=0, DIAGLD=0
A/D Control Extended Register
ADPRC | 0 (00): 12-bit accuracy 1 (01): 10-bit accuracy 2 (10): 8-bit accuracy 3 (11): Setting prohibited |
ACE | A/D Data Register Automatic Clearing Enable 0 (0): Disable automatic clearing 1 (1): Enable automatic clearing |
DIAGVAL | Self-Diagnosis Conversion Voltage Select 0 (00): Setting prohibited when self-diagnosis is enabled 1 (01): 0 volts 2 (10): Reference voltage × 1/2 3 (11): Reference voltage |
DIAGLD | Self-Diagnosis Mode Select 0 (0): Select rotation mode for self-diagnosis voltage 1 (1): Select mixed mode for self-diagnosis voltage |
DIAGM | Self-Diagnosis Enable 0 (0): Disable ADC12 self-diagnosis 1 (1): Enable ADC12 self-diagnosis |
ADRFMT | A/D Data Register Format Select 0 (0): Select right-justified for the A/D data register format 1 (1): Select left-justified for the A/D data register format |